-
1 low voltage power supply
Office equipment: LVPSУниверсальный русско-английский словарь > low voltage power supply
-
2 low-voltage power supply
Универсальный русско-английский словарь > low-voltage power supply
-
3 low voltage power supply test point
Office equipment: LVPS test pointУниверсальный русско-английский словарь > low voltage power supply test point
-
4 manual low-voltage power supply
Military: MLVPSУниверсальный русско-английский словарь > manual low-voltage power supply
-
5 низковольтный источник питания
Russian-English dictionary of telecommunications > низковольтный источник питания
-
6 низковольтный источник питания
Русско-английский политехнический словарь > низковольтный источник питания
-
7 источник питания низкого напряжения
источник питания низкого напряжения
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > источник питания низкого напряжения
-
8 низковольтный источник питания
- low-voltage power supply
- L.V.P.S.
низковольтный источник питания
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
- low-voltage power supply
- L.V.P.S.
Русско-английский словарь нормативно-технической терминологии > низковольтный источник питания
-
9 источник питания низкого напряжения с ручным управлением
Military: manual low-voltage power supplyУниверсальный русско-английский словарь > источник питания низкого напряжения с ручным управлением
-
10 контрольная точка LVPS
1) Engineering: LVPS test point2) Office equipment: low voltage power supply test pointУниверсальный русско-английский словарь > контрольная точка LVPS
-
11 контрольная точка низковольтного блока питания
Office equipment: low voltage power supply test pointУниверсальный русско-английский словарь > контрольная точка низковольтного блока питания
-
12 крышка низковольтного блока питания
1) Engineering: LVPS cover2) Office equipment: low voltage power supply coverУниверсальный русско-английский словарь > крышка низковольтного блока питания
-
13 низковольтный блок питания
Engineering: LVPS, low voltage power supplyУниверсальный русско-английский словарь > низковольтный блок питания
-
14 низковольтный источник питания
Engineering: low-voltage power supply (электро)Универсальный русско-английский словарь > низковольтный источник питания
-
15 главный распределительный щит
- power center
- MSB
- MLVS
- main switchboard
- main low-voltage distribution switchboard
- Main Low Voltage Switchboard
- main distribution switchboard
- main distribution board
- main distributing frame
- m.s.b.
- feeder switchboard
главный распределительный щит (ГРЩ)
Распределительный щит, через который снабжается электроэнергией все здание или его обособленная часть. Роль ГРЩ может выполнять ВРУ или щит низкого напряжения подстанции.
[ПУЭ]
главный распределительный щит
Электрощит в здании, обеспечивающий распределение энергии между подключенными к нему нагрузками и включение аварийных систем при падении напряжения.
[ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]
[ ГОСТ Р 50571.28-2006]EN
main distribution board
board in the building which fulfils all the functions of a main electrical distribution for the supply building area assigned to it and where the voltage drop is measured for operating the safety services
[IEC 60364-7-710, ed. 1.0 (2002-11)]FR
tableau général de distribution
tableau de distribution dans le bâtiment remplissant toutes les fonctions d’un tableau général de distribution pour l’alimentation de la zone qui lui est dédiée et où la chute de tension est mesurée pour le fonctionnement des services de sécurité
[IEC 60364-7-710, ed. 1.0 (2002-11)]
Главный распределительный щит (ГРЩ) на ток 6300 А
[http://www.uzoelectro.ru/catalogue/group-383/product-36465/ ]Тематики
- НКУ (шкафы, пульты,...)
- электроснабжение в целом
- электроустановки
Синонимы
EN
- feeder switchboard
- m.s.b.
- main distributing frame
- main distribution board
- main distribution switchboard
- Main Low Voltage Switchboard
- main low-voltage distribution switchboard
- main switchboard
- MLVS
- MSB
- power center
FR
Русско-английский словарь нормативно-технической терминологии > главный распределительный щит
-
16 напряжение
stress
(механическое) — resistance in a body opposing external force as tension, shear, etc.
- (электрическое) — voltage
- аккумулятора — battery voltage
- аккумулятора, недостаточное — low battery voltage
- бортсети (ла) — aircraft (primary) electrical system voltage
- бортсети (115 в, 400 гц) отсутствует — 115 v 400 hz aircraft primary power (is) removed /unavailable, not exists/
-, вибрационное — vibration stress
- включения (контактора, реле) — pickup voltage
-, внутреннее — internal stress
-, временное — temporary stress
-, вторичное (вспомогательнoe, дополнительное) — secondary voltage
-, входное — input voltage
- выключения (контактора, реле) — dropout voltage
-, высокое (в системе зажигания) — high tension (нт)
-, высокое (в цепях самолетного оборудования) — high voltage danger: high voltage
-, выходное — output voltage
-, двухполупериодное (эл.) — full-wave voltage
-, добавочное (подпорное) — boosting voltage
-, замеряемое вольтметром (vi) должно быть... в — voltmeter (vi) shall read... v
-, запирающее — cutoff voltage
-, зарядное — charging voltage
-, знакопеременное — alternate stress
-, изгибающее — bending stress
- (не) имеется на...(клеммах, шине, штырях) — voltage (not) exists at...
- кручения — torsional stress
- между (клеммами, фазами) — voltage across (terminals, phases)
-, местное — local stress
- накала — filament voltage
- на клеммах — voltage at /across/ terminals
- на клеммах есть — voltage exists /is present/ at terminals
- на клеммах отсутствует (нет) — no voltage exists at terminals
- на обмотке — voltage across winding
- на проводах (проводниках) — voltage on wires /leads/ +2000 volts is present on both multimeter leads.
- на сопротивлении — voltage across resistor
- на шине аккумулятора — battery bus voltage, voltage at on/ battery bus
- на шине генератора — generator bus voltage
- на штыре (шр) — voltage at pin
- неуравновешенного мостика — out-of-balance voltage across bridge
-, номинальное — nominal stress
-, нормальное — normal stress
-, остаточное — residual voltage
- отпускания (контактора, релe) — dropout voltage
-, переменное (перем. тока) — ас voltage, alternating voltage
- питания (напр., 200 в) — supply voltage (of 200 volts), 200-volt supply
- питания (напр., 115 в, 400 гц при 10 а) — power requirements 115 vac, 400 hz, at 10 a)
- переходного процесса — transient voltage
- подпора — anti-backlash voltage
для выбора люфта в кинематической цепи эл. двигателя.
-, подпорное (эл.) — boos(ing) voltage
-, постоянное (постоянного тока) — dс voltage, direct voltage
-, постоянное (по величине) — constant voltage
- привязки — clamp(ing) voltage
- при изгибе — bending stress
- при кручении — torsional stress
-, пробивное (изоляции) — breakdown /puncture/ voltage
-, пробивное (на разряднике) — breakdown voltage
the voltage required to jump an air gap.
- прямоугольной формы — rectangular wave voltage
-, рабочее — operating voltage
-, разрушающее — breaking stress
- рассогласования — error voltage
-, растягивающее — tensile stress
- растяжения — tensile stress
- сжатия — compression stress
- синусоидальной формы — sinusoidal wave voltage
- смещения — bias voltage
- срабатывания (контактора, реле) — pickup voltage
- среза — shear stress
-, срезывающее — shear stress
-, стабилизированное — regulated voltage
the voltage regulator provides the regulated voltage.
-, термическое — thermal stress
-, трогания — pickup voltage
напряжение, вызывающее срабатывание электромагнитных устройств, — the voltage at which a magnetically-operated device starts to operate.
-, ударное — impact stress
-, эталонное — reference voltage
- 115 вольт — voltage /power/ of 115 volts
the voltage should be 115 volts.
подача h.... вольт (постоянного тока) на... — supply of... volts (dс) to...
под н. — energized, alive
не открывать крышку рк при нахождении цепи под напряжением. — do not open the junction box cover, when energized.
распределение высокого н. пo (искровым) свечам — distribution of н.т. impulses to spark plugs
регулирование h. — voltage control
рост h. — voltage rise /increase/
спад h. — voltage drop
увеличение h. — voltage increase /rise/
отключать h. (сети, системы) — de-energize /turn off/ (circuit, system), turn off power supply to supply voltage
подавать h. для преобразования в крутящий момент — transmit voltage for conversion to torque
подавать н. с... к... — supply voltage from... to...
подавать ток напряжением (27) вольт на... — supply (27-) volt power to...
понижать н. — reduce /decrease/ voltage
работать на переменном (постоянном) токе н.... в — be powered by volt ac(dc)
снимать н. (прекращать подачу н., обесточивать) — deenergize, remove electrical power from...
снимать н. c... (пользоваться как источником н.) — pick up voltage from...
снимать н. (разгружать) — unstress
увеличивать н. — increase voltageРусско-английский сборник авиационно-технических терминов > напряжение
-
17 импульсный источник электропитания с коммутацией тока на первичной стороне
импульсный источник электропитания с коммутацией тока на первичной стороне
-In primary switch mode power supplies, the AC mains voltage is first rectified and smoothed and then chopped ("switched"). Chopping means that the DC voltage is switched periodically at a frequency of 40 to 200 kHz using a power transistor.
In contrast to linearly regulated power supplies, the power transistor does not act as a variable resistor but as a switch instead. This generates a square-wave AC voltage that is transformed to the secondary circuit using a high-frequency transformer. In the secondary circuit, the voltage is rectifi ed and smoothed. The quantity of energy transformed to the secondary circuit is controlled, depending on the load, by varying the chopping rate. The longer the transistor is conductive, the higher is the quantity of energy transformed to the secondary circuit ( pulse width modulation).
Due to the use of high-frequency AC voltage, primary switch mode power supplies have the decisive advantage that their transformer can be of much smaller size than required for the transformation of low frequencies. This reduces the weight and the dissipation inside the unit. The effi ciency of these units is between 85 and 95 %. Since the output voltage does not directly depend on the input voltage, these units can be used for a wide input voltage range and can even be supplied with DC voltage. Furthermore, it is possible to buffer short-time mains voltage breakdowns up to 200 ms. However, the power failure buffering time is limited by the size of capacitor C1 since a longer buffering time requires a higher capacity and thus a bigger size of the capacitor. Especially in case of small power supplies this is not desirable.
Therefore, a practicable compromise has to be made between the size of the power supply and the buffering time.
Primary switch mode power supplies can be used for all purposes. For example, they are suitable for the supply of all kind of electronics as well as for electromechanical applications.
[ABB]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > импульсный источник электропитания с коммутацией тока на первичной стороне
-
18 виды коррекции коэффициента мощности
виды коррекции коэффициента мощности
-There are 2 types of power factor correction: fixed or automatic.
Fixed power factor correction consists of inserting, in parallel on the network, a capacitor bank whose total power is provided by the assembly of capacitors of identical or different ratings. The bank is energized by a contactor that simultaneously supplies all the capacitors (a single step).
The inrush current peak, in the case of fixed correction, can reach 30 times the nominal current of the capacitor bank.
An automatic power factor correction system, on the other hand, consists of several capacitor banks of identical or different ratings (several steps), energized separately according to the value of the power factor to be corrected.
An electronic device automatically determines the power of the steps to be energized and activates the relevant contactors.
The inrush current peak, in the case of automatic correction, depends on the power of the steps already on duty, and can reach 100 times the nominal current of the step to be energized.
[ABB]
PFC Types
There are two types of Power Factor Correction - Passive PFC and Active PFC.
Passive PFC uses passive elements like a ferrite core inductor on the AC input. It is very easy to implement in existing power circuits although the power factor is low at 60-80%. The proper AC input voltage (115V or 230V) must also be chosen manually. In addition, significant EMI can still result with a 115V AC source. Of course, a 230V AC source will not have this problem!.
Active PFC, on the other hand, uses a switching regulator with active elements like an IC, FETs (Field Effect Transistors) and diodes to create an active PFC circuit. This circuit allows the power supply to achieve a power factor of up to 95%, significantly reduce harmonics and automatically adjusts the AC input voltage. This means you do not have to manually select the AC input voltage. It works with all voltages from 110V to 240V.
[ http://www.techarp.com/showarticle.aspx?artno=81&pgno=1]
Тематики
EN
Русско-английский словарь нормативно-технической терминологии > виды коррекции коэффициента мощности
-
19 комплектное распределительное устройство среднего напряжения
комплектное распределительное устройство среднего напряжения
-Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.
Safety enclosed switchgear may be classified with respect to purpose of application as follows:
1. General medium- or high- voltage switchgear
2. Primary unit substations
3. Rectifier unit substations
4. Secondary unit substations or power centers
5. General low-voltage switchgear
6. Low-voltage distribution switchboards
7. Motor-control-center switchboards
[American electricians’ handbook]
Medium-voltage switchgear (Fig. 4.115) provides for the required control and metering equipment for generators, transformer supply circuits, feeders, large motors, etc., for systems with voltage up to 15,000 V. A large variety of standardized units is available
FIGURE 4.115 Medium-voltage metal-enclosed switchgear. [Westinghouse Electric Corp.][American electricians’ handbook]
Тематики
- комплектное распред. устройство (КРУ)
Синонимы
EN
Русско-английский словарь нормативно-технической терминологии > комплектное распределительное устройство среднего напряжения
-
20 постоянный ток
постоянный ток
Электрический ток, не изменяющийся во времени.
Примечание — Аналогично определяют постоянные электрическое напряжение, электродвижущую силу, магнитный поток и т. д.
[ ГОСТ Р 52002-2003]Параллельные тексты EN-RU For definition, the electric current called “direct” has a unidirectional trend constant in time.
As a matter of fact, by analyzing the motion of the charges at a point crossed by a direct current, it results that the quantity of charge (Q) flowing through that point (or better, through that cross section) in each instant is always the same.
[ABB]Постоянным током называется электрический ток, значение и направление которого, не изменяются во времени.
Если рассматривать постоянный ток как прохождение элементарных электрических зарядов через определенную точку, то значение заряда (Q), протекающего через эту точку (а вернее через это поперечное сечение проводника) за единицу времени будет постоянным.
[Перевод Интент]Direct current, which was once the main means of distributing electric power, is still widespread today in the electrical plants supplying particular industrial applications.
The advantages in terms of settings, offered by the employ of d.c. motors and by supply through a single line, make direct current supply a good solution for railway and underground systems, trams, lifts and other transport means.
In addition, direct current is used in conversion plants (installations where different types of energy are converted into electrical direct energy, e.g. photovoltaic plants) and, above all, in those emergency applications where an auxiliary energy source is required to supply essential services, such as protection systems, emergency lighting, wards and factories, alarm systems, computer centers, etc..
Accumulators - for example – constitute the most reliable energy source for these services, both directly in direct current as well as by means of uninterruptible power supply units (UPS), when loads are supplied in alternating current.
[ABB]Когда-то электрическая энергия передавалась и распределялась только на постоянном токе. Но и в настоящее время в отдельных отраслях промышленности постоянный ток применяется достаточно широко.
Возможности использования двигателей постоянного тока и передачи электроэнергии по линии с меньшим числом проводников дают неоспоримые преимущества при электроснабжении железных дорог, подземного транспорта, трамваев, лифтов и т. д.
Кроме того, существуют источники постоянного тока, являющиеся преобразователями различных видов энергии непосредственно в электрическую энергию, например, фотоэлектрические станции. Дополнительные источники постоянного тока применяют в аварийных ситуациях для питания систем защиты, аварийного освещения жилых районов и на производстве, систем сигнализации, компьютерных центров и т. д.
Для решения указанных задач наиболее подходящим источником электроэнергии является аккумулятор. Нагрузки постоянного тока получают электропитание непосредственно от аккумулятора. Нагрузки переменного тока – от источника бесперебойного питания (ИБП), частью которого является аккумулятор.
[Перевод Интент]Direct current can be generated:
- by using batteries or accumulators where the current is generated directly through chemical processes;
- by the rectification of alternating current through rectifiers (static conversion);
- by the conversion of mechanical work into electrical energy using dynamos (production through rotating machines).
[ABB]Постоянный ток можно получить следующими способами:
- от аккумуляторов, в которых электрическая энергия образуется за счет происходящих внутри аккумулятора химических реакций;
- выпрямлением переменного тока с помощью выпрямителей (статических преобразователей);
- преобразованием механической энергии в электрическую с помощью генераторов постоянного тока (вращающихся машин).
[Перевод Интент]In the low voltage field, direct current is used for different applications, which, in the following pages, have been divided into four macrofamilies including:
- conversion into other forms of electrical energy (photovoltaic plants, above all where accumulator batteries are used);
- electric traction (tram-lines, underground railways, etc.);
- supply of emergency or auxiliary services;
- particular industrial installations (electrolytic processes, etc.).
[ABB]Можно выделить четыре области применения постоянного тока в низковольтных электроустановках:
- преобразование различных видов энергии в электрическую (фотоэлектрические установки с аккумуляторными батареями);
- энергоснабжение транспорта на электрической тяге (трамваи, метро и т. д.)
- электропитание аварийных или вспомогательных служб;
- специальные промышленные установки (например, с использованием электролитических процессов и т. п.).
[Интент]Тематики
- электротехника, основные понятия
Синонимы
EN
Русско-английский словарь нормативно-технической терминологии > постоянный ток
- 1
- 2
См. также в других словарях:
Power supply — For the Budgie album, see Power Supply (album). A vacuum tube rackmount adjustable power supply, capable of +/ 1500 volts DC, 0 to 100mA output, with amperage limiting capability. A power supply is a device that supplies electrical energy … Wikipedia
Power supply rail — A power supply rail or voltage rail refers to a single voltage provided by a power supply unit (PSU) relative to some understood ground. Although the term is generally used in electrical engineering, most people encounter it in the context of… … Wikipedia
Power supply unit (computer) — Power supply unit with top cover removed A power supply unit (PSU) supplies direct current (DC) power to the other components in a computer. It converts general purpose alternating current (AC) electric power from the mains (110 V to… … Wikipedia
Low-voltage differential signaling — Low voltage differential signaling, or LVDS, is an electrical signaling system that can run at very high speeds over inexpensive twisted pair copper cables. It was introduced in 1994, and has since become very popular in computers, where it forms … Wikipedia
Low-voltage positive emitter-coupled logic — Low voltage positive emitter coupled logic, or LVPECL, is a power optimized version of the Positive emitter coupled logic (PECL) technology, requiring a positive 3.3V instead of 5V supply. LVPECL is a differential signaling system and mainly used … Wikipedia
Low voltage ride through — In electricity supply and generation,low voltage ride through (LVRT) is what an electric device, especially wind generator, may be required to be capable to do when the voltage in the grid is temporary reduced due to a fault or load change in the … Wikipedia
Switched-mode power supply — switched mode power supply. A bridge rectifier B Input filter capacitors C Transformer D output filter coil E output filter capacitors ] A switched mode power supply, switching mode power supply or SMPS, is an electronic power supply unit (PSU)… … Wikipedia
Remote Area Power Supply — A Remote Area Power Supply (RAPS) is a system that provides electricity in remote locations, without requiring connection to an electricity distribution system. RAPS is now typically called a Stand alone Power Systems (SAPS or SPS), as the same… … Wikipedia
Uninterruptible power supply — A small free standing UPS … Wikipedia
Extra-low voltage — IEC voltage range AC DC defining risk High voltage (supply system) > 1000 Vrms > 1500 V electrical arcing Low voltage (supply system) 25–1000 Vrms 60–1500 V electrical shock Extra low voltage (supply system) < 25 V … Wikipedia
Welding power supply — A welding power supply is a device that provides an electric current to perform welding. Welding usually requires high current (over 80 amperes) and it can need above 12,000 amps in spot welding. Low current can also be used; welding two razor… … Wikipedia